Shopping security
In summary, the Siglent SSA3021X PLUS is a benchtop spectrum analyzer covering 9 kHz to 2.1 GHz designed for general RF spectrum measurement, educational use, production test, and field RF work. Per the datasheet, the SSA3021X PLUS provides resolution bandwidths from 1 Hz to 3 MHz (10 MHz EMI), -161 dBm typical displayed average noise level with the preamplifier on, -98 dBc/Hz typical SSB phase noise at 1 GHz / 10 kHz offset, and a 10.1 inch capacitive multi-touch WXGA display. Standard interfaces include LAN, USB Device, USB Host, and HDMI; SCPI / LabVIEW / IVI remote control is supported.
The SSA3021X PLUS is used for general RF spectrum measurement — channel power, ACPR, occupied bandwidth, harmonic distortion, and third-order intercept — plus pre-compliance EMI sweeps and basic AM / FM / ASK / FSK modulation analysis. Per the datasheet, target applications include broadcast and CATV monitoring, cellular site work, IoT and ISM-band development, WLAN and Bluetooth surveys, RF education, and bench-level production verification.
The SSA3021X PLUS is positioned as Siglent's value-tier general-purpose RF spectrum analyzer. Per the manufacturer datasheet, it provides identical measurement vocabulary — channel power, ACPR, occupied bandwidth, harmonic distortion, and third-order intercept — to higher-priced premium-tier instruments, at a price point well-suited to education, startups, and bench-level production verification. It is not the right choice when the application requires the lowest available phase noise or the widest available dynamic range; for those applications, a premium-tier instrument is required.
Per the manufacturer datasheet, the standard ship kit includes: a Quick Start guide, a region-appropriate AC power cord, and a USB cable.
| Frequency range | 9 kHz to 2.1 GHz |
|---|---|
| Frequency resolution | 1 Hz |
| Span range | 0 Hz (Zero Span), 100 Hz to maximum frequency |
| Internal reference (10 MHz) | Aging < 1 ppm/yr; temperature stability < 1 ppm (0-50 °C) |
| OCXO option (10M_OCXO) | Aging < 0.05 ppm/yr; stability < 0.05 ppm (0-50 °C) |
| RBW (-3 dB) | 1 Hz to 3 MHz, 1-3-10 sequence |
| VBW (-3 dB) | 1 Hz to 3 MHz, 1-3-10 sequence |
| EMI filter (-6 dB) | 200 Hz, 9 kHz, 120 kHz, 1 MHz (CISPR 16) |
| Measurement range, 100 kHz to 2.1 GHz (preamp off) | DANL to +30 dBm |
|---|---|
| Reference level | -100 dBm to +30 dBm, 1 dB steps |
| Preamplifier | ~20 dB nominal, can be turned on or off |
| Input attenuation | 0 to 50 dB, 1 dB steps |
| Maximum continuous power | +30 dBm (1 W) |
| Maximum input DC voltage | ± 50 VDC |
| Traces / detectors | 4 / Pos-peak, Neg-peak, Sample, Normal, Average |
| Level units | dBm, dBmV, dBµV, V, W |
| DANL, preamp off (100 kHz to 7.5 GHz) | -130 dBm (1 MHz to 1.5 GHz), normalized to 1 Hz |
| DANL, preamp on (typ.) | -161 dBm, 1 MHz to 1.5 GHz |
| SSB phase noise at 1 GHz, 10 kHz offset | < -95 dBc/Hz; -98 dBc/Hz typical |
| Absolute amplitude accuracy at 50 MHz | ± 0.4 dB |
| RF input VSWR (att ≥ 10 dB) | < 1.5 |
| Second harmonic intercept (SHI) | +45 dBm typical |
|---|---|
| Third-order intercept (TOI) | +10 dBm typical |
| Residual response | < -90 dBm |
| Sweep time (Span ≥ 100 Hz) | 1 ms to 4000 s |
| Sweep time (Zero Span) | 1 µs to 6000 s |
| Sweep points | 751 |
| Trigger source | Free Run, Video, External, Frequency Mask (R variant) |
| External trigger | TTL, rising or falling edge |
| Advanced Measurement Kit (AMK) | Channel Power, ACPR, OBW, T-Power, Harmonic, TOI |
|---|---|
| EMI Measurement (EMI option) detectors | Peak, Average, Quasi-Peak (CISPR 16-1-1) |
| EMI limit standards | EN 55022, FCC Part 15, user defined |
| Modulation Analysis (AMA option) | AM, FM, ASK, FSK demodulation |
| AM modulation rate / depth | 20 Hz to 100 kHz / 5% to 95% |
| FM modulation rate / deviation | 20 Hz to 200 kHz / 1 kHz to 200 kHz |
| Reflection (REM option) | Built-in tracking generator support for reflection measurement (X model) |
| TG output frequency range | 100 kHz to 2.1 GHz (X / Plus models) |
|---|---|
| TG output power range | -40 dBm to 0 dBm, 1 dB steps |
| TG output flatness | ± 3 dB (100 kHz to 2.1 GHz) |
| TG source match VSWR | < 1.6 |
| TG harmonic distortion | < -25 dBc |
| RF input / TG output | N-type female, 50 Ω (TG output on Plus / X models) |
|---|---|
| USB / LAN | USB Host 2.0 + USB Device 2.0 / 10/100 Base, RJ-45 |
| Video / Audio | HDMI / 3.5 mm jack |
| 10 MHz reference I/O | BNC-F, 50 Ω |
| External trigger | BNC-F, TTL |
| Remote protocols | SCPI / LabVIEW / IVI over USB-TMC, VXI-11, Socket, Telnet; GPIB via USB-GPIB adapter; HTML5 web browser |
| Display | TFT LCD, 1280 × 800, 10.1 inch multi-touch capacitive |
|---|---|
| Internal storage | ≥ 1 GB |
| Dimensions (W×H×D) / weight | 365 × 207 × 134 mm / approx. 4.0 kg (8.8 lb) |
| AC source | 100-240 V, 47.5-440 Hz; 45 W maximum |
| Operating temperature / humidity | 0 to 50 °C; ≤ 90% RH at 30 °C, non-condensing |
| Safety / EMC | EN 61010-1, IEC 61010-1, UL / CSA 61010-1; EN 61326-1; RoHS 2011/65/EU |
The SSA3000X family includes base 'X' models, 'Plus' variants (adding extended functionality), and 'R' real-time variants. Software options (AMK Advanced Measurement Kit, EMI Measurement, AMA Modulation Analysis, REM Reflection Measurement, OCXO precise reference) are field-upgradable. Confirm required options at the time of order.
This webpage was written by a human with an A.I. "Intern", which may contain errors. Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.
Ships within 48 hours · Estimated delivery Jun 21 - Jun 26
US$40
Get nowSign up to your membership to get coupons up to
15%
Get nowOpportunity to enjoy order discount up to 15% off
Top-Converting Item to Boost Your Average Order