Shopping security
Built for tradies: The Embraco Aspera NEU2168GK is a low-temperature LBP hermetic compressor sized for display freezers, reach-ins and merchandisers. It helps licensed techs finish installs faster with clean starts and solid pull-down, no dramas.
Heads-up on refrigerant: most NEU2168GK engineering codes are set up for R404A LBP. If you’re running R134a low temp, confirm the nameplate/engineering code or contact us for the correct variant. Fair dinkum, matching the code saves call-backs.
Quick yarn: Perth summer arvo, corner-store merchandiser icing up and drifting warm by lunch. We slotted in a NEU2168GK, fitted a fresh drier, nitrogen-tested, pulled <500 microns and weighed in to spec. Cabinet was back at setpoint before smoko. That’s the difference when the duty and engineering code match — too easy.
Need matching tooling and spares? Our Refrigeration collection keeps the whole system humming.
Always replace the liquid-line drier and purge with nitrogen while brazing. Log your vacuum with a micron gauge, isolate for a decay test, then weigh the charge. It’s a small step that chops down call-backs. She’ll be right.
| Item | Spec |
|---|---|
| Model / Engineering code | NEU2168GK / 959MA51 (check nameplate) |
| Application | LBP (low back pressure) |
| Refrigerant (typ.) | R404A (variants exist; verify if using R134a) |
| Displacement | 14.28 cm³ |
| Cooling capacity (EN12900) | ~403–415 W @ −35 °C evap / +40 °C cond (LBP) |
| Efficiency (LBP) | ~1.06–1.11 W/W |
| Power supply | 220–240 V, 50 Hz, 1-phase |
| Motor / Start | CSIR / High Start Torque |
| Start capacitor (typ.) | 88–108 µF / 330 V (current relay MTRPH-0055-65) |
| RLA / LRA (50 Hz) | ~4.4 A / ~22 A |
| Oil / charge | POE (ester) ISO 22 / ~350 ml |
| Height / Weight | 206 mm / ~11.6 kg |
| Tube stubs | Suction Ø 8.1 mm; Discharge Ø 6.1 mm; Process Ø 6.1 mm |
| Base | UNI (European) |
Key specs verified against Embraco/partner datasheets and distributors. Always confirm the exact engineering code for your refrigerant and duty.
Backed by manufacturer warranty. HVAC Shop supports returns per our Shipping & Returns policy. Australian consumer guarantees apply.
Often yes for R404A LBP merchandisers if the duty matches. Check the base footprint (UNI), stub sizes (8.1/6.1 mm), and capacity at your design temps. For R134a low temp, confirm the engineering code or ask us for the right variant.
Typical start capacitor is 88–108 µF / 330 V with a current relay. Always match the nameplate/datasheet.
Pressure-test with nitrogen, purge while brazing, pull a deep dry vacuum (<500 microns) and do a decay test. Weigh in the charge and log SH/SC. If your vac gear needs an upgrade, see our pumps below — they’re a ripper for tight systems.
For Australian safety and handling guidance, see AIRAH’s Refrigerant Handling Codes of Practice.
Ships within 48 hours · Estimated delivery Jun 21 - Jun 26
US$40
Get nowSign up to your membership to get coupons up to
15%
Get nowOpportunity to enjoy order discount up to 15% off
Top-Converting Item to Boost Your Average Order